KukaVariableProxyMaster

Purpose​

KukaVariableProxyMaster reads or writes one KUKA KRC4 controller variable by name through the KRC4 variable proxy. This plugin does not provide program start, stop, or reset methods.

Open the plugin​

Open Development Configuration → Collection Configuration, create a device, and select KukaVariableProxyMaster under Collection Plugin.

Supported channel and data types​

Channel typeCheck before configuration
TCP clientConfirm the controller IP, port, and network reachability from the gateway.

Optional data types: Byte and String.

Address rules​

  • The address is the controller variable name, for example $POS_ACT. Names and values use UTF-8.
  • Periodic collection supports Byte and String. A String variable must specify len, for example $PRO_NAME[];len=32;encoding=UTF-8.
  • Each variable is requested independently; variables are not packed into one request.

Special methods​

MethodPurposeParameters
ReadVariableTextAsyncRead one KUKA variable.address=variable name
WriteVariableTextAsyncWrite one KUKA variable.address=variable name, value=variable value

A write changes controller memory. Confirm that the equipment is in an operable state and prepare stop or rollback measures before execution.

Functions​

FunctionPurpose
Read variableRead one KUKA variable without changing controller state.
Write variableWrite a text value to a named variable; this changes controller memory.
Debug resultShow the returned value or the result and error of the write operation.

Device debug​

Open Development Configuration → Collection Configuration, select the KukaVariableProxyMaster device, and open More Functions → Debug.

KukaVariableProxyMaster protocol debug panel

Read one variable first. A write requires a second confirmation because it changes controller memory.

Verify the configuration​

  1. Read a read-only variable such as $POS_ACT and compare the returned value with the teach pendant.
  2. For periodic string reads, set len and encoding=UTF-8 in the address and confirm that the complete text is returned.
  3. Create several variables only after one variable works; check response time and controller load one by one.
  4. Verify writes only on an approved test variable. Read the same variable again after writing.

Troubleshooting​

SymptomCheck
Variable read has no responseCheck TCP address, port, KRC4 variable-proxy service, and variable name casing.
String is truncatedIncrease len to hold the complete value and keep encoding=UTF-8.
Write failsConfirm that the variable is externally writable, the value format matches the controller type, and inspect the proxy error.
Program control is not availableThis plugin provides only single-variable read and write. Use a KUKA plugin that supports program operations.